Warranty: | 2 Years |
---|---|
Nature of Source Flow: | Passive inverter |
Phase: | Single |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Introducing our HS series products, designed for high-efficiency and low-loss operation. These products feature U-shaped transformers that support the generator start function, providing voltage dual output for versatile usage. Users can easily set the charging mode based on their specific environment needs. Our products offer integrated management, boasting a high conversion rate, low power consumption, and a robust load capacity. The HS series is the pinnacle of industrial frequency inverters.
Model HS | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | ||||
Inverter Output |
Continuous Output Power |
1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10000W | 12000W | |||
Surge Rating(20ms) |
3KW | 6KW | 9KW | 12KW | 15KW | 18KW | 24KW | 30KW | 36KW | ||||
Output Waveform |
Pure Sine wave/Same as input(Bypass Mode) | ||||||||||||
Nominal Efficiency |
>88%(Peak) | ||||||||||||
Line Mode Efficiency |
>95% | ||||||||||||
Power Factor | 0.9- 1.0 | ||||||||||||
Nominal Output Voltage rms |
100- 110- 120Vac / 220-230-240Vac | ||||||||||||
Output Voltage Regulation |
±10% RMS | ||||||||||||
Output Frequency |
50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||||||||
Short Circuit Protection |
Yes( 1sec after fault ) | ||||||||||||
Typical transfer Time |
10ms(Max) | ||||||||||||
THD | < 10% | ||||||||||||
DC Input |
Nominal Input Voltage |
12.0Vdc / 24.0Vdc / 48.0Vdc |
24.0Vdc / 48.0Vdc | 48.0Vdc | |||||||||
Minimum Start Voltage |
10.0Vdc / 10.5Vdc for 12Vdc Mode |
*2 for 24Vdc, *4 for 48Vdc; | |||||||||||
Low Battery Alarm |
10.5Vdc / 11.0Vdc for 12Vdc Mode |
||||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc for 12Vdc Mode |
||||||||||||
High Voltage Alarm |
16.0Vdc for 12Vdc Mode | ||||||||||||
Low Battery voltage recover |
15.5Vdc for 12Vdc Mode | ||||||||||||
Idle Consumption-Se arch Mode |
< 25 W when Power Saver On.(Refer to Table ) | ||||||||||||
Charger | Output Voltage | Depends on battery type (Refer to Table 2.5.2) | |||||||||||
Charger Breaker Rating |
10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||||
Max Charge Power Rate |
1/3 Rating Power (Refer to Table 2.5.3) | ||||||||||||
Battery Initial Voltage for Start |
10- 15.7Vdc for 12Vdc Mode |
*2 for 24Vdc, *4 for 48Vdc; | |||||||||||
Over Charge Protection S.D. |
15.7Vdc for 12Vdc Mode | ||||||||||||
BTS | Battery Temperature Sensor (Optional) |
Yes(Refer to the table ) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature. |
|||||||||||
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) | |||||||||||
Nominal Voltage | 100- 110- 120Vac / 220-230-240Vac | ||||||||||||
Max Input AC Voltage |
150VAC For 120Vac LV Mode ;300VAC For 230Vac HV Mode; | ||||||||||||
Nominal Input Frequency |
50Hz or 60Hz | ||||||||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | ||||||||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | ||||||||||||
Overload protection (SMPS load) |
Circuit Breaker | ||||||||||||
Output Short circuit protection |
Circuit Breaker | ||||||||||||
Bypass breaker rating |
10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||||
Transfer switch rating | 30Amp | 40Amp | 80Amp | ||||||||||
Bypass without battery connected |
Yes (Optional) | ||||||||||||
Max bypass current |
30Amp | 40Amp | 80Amp | ||||||||||
Mechanical Specifications |
Mounting | Wall Mount | |||||||||||
Inverter Dimensions(L*W *H) |
340* 420* 200mm |
425*375*200mm | 560*420*235mm | 655*490*240mm | |||||||||
Inverter housing size (L*W*H) |
415* 440* 300mm |
500*495*300mm | 660*470*310mm | 720*470*290mm | |||||||||
Inverter Weight(Solar Chg)KG |
16 | 19.5 | 24 | 31.5 | 33.5 | 37.5 | 56.5 | 58.5 | 61.5 | ||||
Shipping Weight(Solar Chg)KG |
19 | 22 | 26.5 | 38 | 40 | 44 | 63.5 | 66 | 68.5 | ||||
Display | Status LEDs / Status LEDs+LCD | ||||||||||||
Standard Warranty |
2 Years (Optional) |