Warranty: | 2 Years |
---|---|
Nature of Source Flow: | Passive inverter |
Phase: | Single |
Output Power: | 1000W |
Certification: | CE, ROHS, ISO9001 |
Brand: | Star The Force |
Samples: |
---|
Suppliers with verified business licenses
HV-PV solar off-grid vertical inverter series products areBuilt-in solar MPPT/PWM controller (optional), and complementary with mains Inverter control all-in-one machine, users only need external solar modules and batteries,It can form an off-grid power generation system;The user can set the sleep mode according to the actual situation,The solar energy priority mode is a multi-functional and intelligent inverter control all-in-one machine.
1. pure sine output is suitable for various loads. it can be used with mixedpower supply such as mains,diesel generators automatic switching off
Electrical Specifications | |||||||||||||
Model HV-PV | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | ||||
Inverter output |
rated power | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | |||
Peak power (2 seconds) |
3.0KW | 6.0KW | 9.0KW | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | ||||
Output voltage waveform |
Pure sine wave (mains or generator) | ||||||||||||
Rated efficiency | >88%(Peak) | ||||||||||||
Online mode efficiency |
>95% | ||||||||||||
Power factor | 0.9- 1.0 | ||||||||||||
Rated output voltage |
100- 110- 120Vac / 220-230-240Vac | ||||||||||||
Output frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||||||||
Short circuit | Yes, protection after 1 second short circuit | ||||||||||||
protection | |||||||||||||
Typical switching time |
10ms (maximum) | ||||||||||||
Total harmonic distortion |
< 10% | ||||||||||||
DC input | Rated input voltage |
12.0Vdc / 24.0Vdc / 48.0Vdc |
24.0Vdc / 48.0Vdc | 48.0Vdc/60.0Vdc/72.0Vdc | |||||||||
Minimum starting voltage |
10.0Vdc / 10.5Vdc for 12Vdc Mode |
*2 for 24Vdc,*4 for 48Vdc*5 60VdcVdc *6 72Vdc |
|||||||||||
Low battery voltage alarm |
10.5Vdc / 11.0Vdc for 12Vdc Mode |
||||||||||||
Low voltage cut out |
10.0Vdc / 10.5Vdc for 12Vdc Mode |
||||||||||||
High voltage cutting |
16.0Vdc for 12Vdc Mode | ||||||||||||
Low voltage recovery |
15.5Vdc for 12Vdc Mode | ||||||||||||
Protect | Rated input voltage |
100- 110- 120Vac / 220-230-240Vac | |||||||||||
Maximum input voltage |
150VAC For 120Vac LV Mode ;300VAC For 230Vac HV Mode; | ||||||||||||
Rated input frequency |
50Hz or 60Hz | ||||||||||||
Low frequency cut out |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | ||||||||||||
High frequency cut out |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | ||||||||||||
Overload protection |
yes | ||||||||||||
Output short circuit protection |
yes | ||||||||||||
Maximum bypass current |
30Amp | 40Amp | 80Amp | ||||||||||
Charge controller |
The output voltage |
Depends on battery type | |||||||||||
Charging circuit breaker specifications |
15A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||||
Maximum charging current |
See detailed table | ||||||||||||
Starting voltage | 10.5- 15.7Vdc for 12Vdc Mode |
*2 for 24Vdc, *4 for 48Vdc;*6 72Vdc | |||||||||||
Overcharge protection shutdown point |
more than the 15.8Vdc for 12Vdc Mode |
||||||||||||
Solar Controller parameter |
Solar system voltage |
MPPT12V/24V/36V/48V automatic recognition | |||||||||||
Open circuit voltage of photovoltaic panel |
18~150Vdc@ 12V 35~150Vdc@24V 60~150Vdc@48V | ||||||||||||
Rated charging current |
30A- 120A (optional) | ||||||||||||
Charging efficiency |
97.6% | ||||||||||||
Rechargeable battery type |
Valve-regulated lead-acid battery Gel battery Lithium battery | ||||||||||||
charging method | Four-stage charging: constant current charge, constant voltage charge, float charge, equal charge |
||||||||||||
safety protection | Solar panel short circuit protection, overcharge protection, over discharge protection, overload protection |
||||||||||||
PV module utilization |
12V/24V/48V | W99. 97% | |||||||||||
Input Features | |||||||||||||
MPPT working Voltage |
12V | DC18V-DC150V | |||||||||||
24V | DC34V-DC150V | ||||||||||||
48V | DC65V-DC150V | ||||||||||||
Max PV input Voltage |
12V/24V/48V | DC170V | |||||||||||
Over voltage protection point |
12V/24V/48V | DC175V | |||||||||||
Over voltage input recovery point |
12V/24V/48V | DC170V | |||||||||||
MAX solar input power |
12V System | 420W | 570W | 700W | 900W | 1140W | 1400W | ||||||
24V System | 840W | 1130W | 1400W | 1700W | 2260W | 2600W | |||||||
48V System | 1650W | 2270W | 2800W | 3400W | 4540W | 5600W | |||||||
Output Features | Same as battery voltage | ||||||||||||
Battery Type(The default isislead-acid )maint enance-free battery) |
12V/24V/48V/96V | Lead-acid maintenance-free batteries, gel batteries, liquid batteries, lithium batteries (You can also customize to charge other types of batteries) |
|||||||||||
Mechanical parameters |
Install | Wall mount | |||||||||||
Inverter size (length * width * height) |
380*215 *360mm |
490*215*410mm | 490*215*410mm | 480*300*715mm | |||||||||
Inverter shell size (length * width * height) |
- | - | 550*320*820mm | ||||||||||
Net weight of inverter with solar rear KG |
- | - | - | 63 | 65.5 | 66.5 | |||||||
Package includes solar rear unit net weight KG |
- | - | - | - | - | - | 71.5 | 74 | 75 | ||||
show | Status LEDs / Status LEDs+LCD | ||||||||||||
Standard warranty | 2 year |
Suppliers with verified business licenses