Warranty: | 2 Years |
---|---|
Nature of Source Flow: | Passive inverter |
Phase: | Single |
Still deciding? Get samples of US$ 240/Piece
Request Sample
|
Suppliers with verified business licenses
Introducing the HS-PV series inverter from Ningbo Star The Force International Trade Co., Ltd. This high-end product is designed for off-grid power generation systems, offering a range of advanced features:
With the HS-PV series inverter, users can easily set the charging mode according to their environment, making it a convenient and reliable choice for various applications. Simply connect external solar modules and batteries to create a powerful off-grid power generation system.
Experience the next level of industrial frequency inverters with the HS-PV series. Upgrade to a smarter and more efficient power solution today!
Electrical Specifications | ||||||||||||||
Model HS-PV | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | |||||
Inverter output |
rated power | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | ||||
Peak power (2 seconds) |
3.0KW | 6.0KW | 9.0KW | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | |||||
Output voltage waveform |
Pure sine wave (mains or generator) | |||||||||||||
Rated efficiency | >88%(Peak) | |||||||||||||
Online mode efficiency |
>95% | |||||||||||||
Power factor | 0.9- 1.0 | |||||||||||||
Rated output voltage |
100- 110- 120Vac / 220-230-240Vac | |||||||||||||
Output frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||||||||
Short circuit | Yes, protection after 1 second short circuit | |||||||||||||
protection | ||||||||||||||
Typical switching time |
10ms (maximum) | |||||||||||||
Total harmonic distortion |
< 10% | |||||||||||||
DC input |
Rated input voltage |
12.0Vdc / 24.0Vdc / 48.0Vdc |
24.0Vdc / 48.0Vdc | 48.0Vdc/60.0Vdc/72.0Vdc | ||||||||||
Minimum starting voltage |
10.0Vdc / 10.5Vdc for 12Vdc Mode |
*2 for 24Vdc,*4 for 48Vdc*5 60VdcVdc *6 72Vdc |
||||||||||||
Low battery voltage alarm |
10.5Vdc / 11.0Vdc for 12Vdc Mode |
|||||||||||||
Low voltage cut out |
10.0Vdc / 10.5Vdc for 12Vdc Mode |
|||||||||||||
High voltage cutting |
16.0Vdc for 12Vdc Mode | |||||||||||||
Low voltage recovery |
15.5Vdc for 12Vdc Mode | |||||||||||||
Protect | Rated input voltage |
100- 110- 120Vac / 220-230-240Vac | ||||||||||||
Maximum input voltage |
150VAC For 120Vac LV Mode ;300VAC For 230Vac HV Mode; | |||||||||||||
Rated input frequency |
50Hz or 60Hz | |||||||||||||
Low frequency cut out |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||||||||||||
High frequency cut out |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||||||||||||
Overload protection |
yes | |||||||||||||
Output short circuit protection |
yes | |||||||||||||
Maximum bypass current |
30Amp | 40Amp | 80Amp | |||||||||||
Charge controller |
The output voltage |
Depends on battery type | ||||||||||||
Charging circuit breaker specifications |
15A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | |||||
Maximum charging current |
See detailed table | |||||||||||||
Starting voltage | 10.5- 15.7Vdc for 12Vdc Mode |
*2 for 24Vdc, *4 for 48Vdc;*6 72Vdc | ||||||||||||
Overcharge protection shutdown point |
more than the 15.8Vdc for 12Vdc Mode |
|||||||||||||
Solar Controller parameter |
Solar system voltage |
MPPT12V/24V/36V/48V automatic recognition | ||||||||||||
Open circuit voltage of photovoltaic panel |
18~150Vdc@12V 35~150Vdc@24V 60~150Vdc@48V | |||||||||||||
Rated charging current |
30A- 120A (optional) | |||||||||||||
Charging efficiency |
97.6% | |||||||||||||
Rechargeable battery type |
Valve-regulated lead-acid battery Gel battery Lithium battery | |||||||||||||
charging method | Four-stage charging: constant current charge, constant voltage charge, float charge, equal charge |
|||||||||||||
safety protection | Solar panel short circuit protection, overcharge protection, over discharge protection, overload protection |
|||||||||||||
PV module utilization |
12V/24V/48V | W99. 97% | ||||||||||||
Input Features | ||||||||||||||
MPPT working Voltage |
12V | DC18V-DC150V | ||||||||||||
24V | DC34V-DC150V | |||||||||||||
48V | DC65V-DC150V | |||||||||||||
Max PV input Voltage |
12V/24V/48V | DC170V | ||||||||||||
Over voltage protection point |
12V/24V/48V | DC175V | ||||||||||||
Over voltage input recovery point |
12V/24V/48V | DC170V | ||||||||||||
MAX solar input power |
12V System | 420W | 570W | 700W | 900W | 1140W | 1400W | |||||||
24V System | 840W | 1130W | 1400W | 1700W | 2260W | 2600W | ||||||||
48V System | 1650W | 2270W | 2800W | 3400W | 4540W | 5600W | ||||||||
Output Features | Same as battery voltage | |||||||||||||
Battery Type(The default isislead-acid )maint enance-free battery) |
12V/24V/48V/96V | Lead-acid maintenance-free batteries, gel batteries, liquid batteries, lithium batteries (You can also customize to charge other types of batteries) |
||||||||||||
Mechanical parameters |
Install | Wall mount | ||||||||||||
Inverter size (length * width * height) |
340*420 *200mm |
425*375*200mm | 560*420*235mm | 655*490*240mm | ||||||||||
Inverter shell size (length * width * height) |
415*440 *300mm |
500*495*300mm | 660*470*310mm | 720*470*290mm | ||||||||||
Net weight of inverter with solar rear KG |
16 | 21.5 | 28.2 | 33 | 35.5 | 38 | 58 | 60.5 | 63 | |||||
Package includes solar rear unit net weight KG |
19 | 24 | 30.8 | 39.5 | 42 | 45 | 65.5 | 67 | 70.5 | |||||
show | Status LEDs / Status LEDs+LCD | |||||||||||||
Standard warranty | 2 year |